Specifications

back to technical >>

Interloc provide a complete specification service which includes a site investigation, (if appropriate) specification report writing with project specific detailing clauses as well as technical drawings.

If however you would rather do the specifications yourself please find below examples of some specifications reflecting the most commonly used applications for the Envirotech EVA single ply product. These specifications have been written in a way that allows both specifiers and Interloc approved contractors to delete the irrelevant clauses. If you do not find the relevant specification suited to your project please contact us.

These specifications are generic and do not necessarily reflect the individual aspects and details of the roofing project and therefore Interloc recommend that all specifications are checked and signed off by our technical team.

Each specification is written in the following format:

Introduction letter
List of contents
Condition report
Suggested specification
Specifications 1-4 are examples for refurbishment projects

1- Overlay the existing roof with Envirotech EVA fleece backed membrane incorporating new insulation.
Click here for specification

Outline specification and build up:-
Existing timber or metal deck with existing waterproofing still in place
Vapour control layer
Polyurethane insulation
Envirotech EVA fleece backed waterproofing fully adhered

2- Overlay the existing roof with Envirotech EVA fleece backed membrane with no additional insulation.
Click here for specification

Outline specification and build up:-
Existing timber or metal deck with existing waterproofing still in place
Envirotech EVA fleece backed waterproofing fully adhered

3- Strip off the existing waterproofing down to the existing deck incorporating new insulation and Envirotech EVA fleece backed membrane
Click here for specification

Outline specification and build up:-
Existing waterproofing stripped off and removed
Existing timber or metal deck
Vapour control layer
Polyurethane insulation
Envirotech EVA fleece backed waterproofing fully adhered  

4- Strip off the existing waterproofing down to the existing deck with no additional insulation and Envirotech EVA fleece backed membrane.
Click here for specification

Outline specification and build up:-
Existing waterproofing stripped off and removed
Existing timber or metal deck
Envirotech EVA fleece backed waterproofing fully adhered


Specifications 5-8 are examples for new buildings and new build extensions


5- Fully adhered Envirotech EVA fleece backed membrane with new insulation
Click here for specification

Outline specification and build up:-
New timber, metal or concrete deck
Vapour control layer
90mm Polyurethane insulation
Envirotech EVA fleece backed waterproofing fully adhered

6- Fully sdheared Envirotech EVA fleece backed membrane with no insulation.
Click here for specification

Outline specification and build up:-
New timber, metal or concrete deck
Envirotech EVA fleece backed waterproofing fully adhered

7- Mechanically fixed Envirotech EVA standard membrane with insulation.
Click here for specification

Outline specification and build up:-
New timber, metal or concrete deck
Vapour control layer
90mm Polyurethane insulation
Envirotech EVA standard waterproofing mechanically fixed

8- Mechanically fixed Envirotech EVA standard membrane with no insulation.
Click here for specification   

Outline specification and build up:-
New timber, metal or concrete deck
Envirotech EVA standard waterproofing mechanically fixed

For mechanically fixed systems Interloc Building Solutions technical department must be consulted to determine the exact fixing layout and fixing spacings. Factors that will determine this are: 

Location of the building                           Click here for mechanical fixing layout example
Height of the building
If it is in an urban or rural area
Proximity to the coast line
Roof layout


 

back to top >>